This series of devices regard high-performance single-chip micro computers the basic hardware, adopt AC sampling, digital integration, filtration technology, can trace and compensate the reactive electricity intelligently. This method has prevented the problem caused when contactor input and cut off the capacitor, through compounding switch (input and cutoff mode of combining with crystal braking-tube and contactor ) and input and cutoff over-zero,so as to prevent the "surge current"  caused while capacitor inputting. Three is no mechanical movement, and electric arc. No harmonic wave fast compensating speed that is especially suitable for using at the place of frequent  inputting and cutting. And this method can lengthen the service life of the main  device of capacitor. It has reason-able structure, modern techniques, mainly apples to the low-voltage power network to increase power factor and reduce reactive loss, improve power supply quality. It is the new generation economizing on electricity products and also is one of the advanced compensator both at domestic and inter-national at present.


Model and implication



Main Characteristics

Small volume, convenient  for installing and maintenace, good water proof performance, and can be used for both outdoor and indoor.

Controlling  parameter  full digital operation, convenient for using, the data cannot lose when power off. 

Digital display power network power factor, reactive power, voltage, current (one side), control parameter.

With the function of over-voltage, under-voltage judgment displays and fast cut off the compensated capacitor group.

With two working modes of manual and auto compensation.

It has the function of auto selecting the best mode to input and cutoff compens ation according to the result of capacitor group manual input.

With two working  modes of  cycle or optimizing input and cutoff, the compensation Includes controlling mode of 1:1:1:1, 1:2:2:2, 1:2:4:8, the compensator will automatically distinguish its code working mode of manual input duplexure capacitance value, it works according to the correspondence code mode.

With two working modes of power factor or reactive power;

Compensating mode: ①Phase splitting compensation

②Phase splitting and three-phase compensation 

③Three-phase compensation.

Control mode: ①Crystal braking-tube input and cutoff  

②Compound switch input and cutoff



Technical Charactersitics

Service conditions: Altitude≤2000m, ambient temperature -25℃~50℃, humidity ≤90% at 20℃; ≤90% at 40℃, Installing gradient ≤5°.

Usage voltage range:(0.85~1.10)times rated voltage.

Max. Allowable over-current: 1.3 times rated current.

Control loop no: 1~12(settable).

Input and cutofftime: dynamic state 100ms~30S, static state 1~250S(settable).

Under-voltage protection: 340V/180V; return difference 6V.

Over-voltage protection: 380-500/230-260V; return difference 6V; (settable).

CT variation: 50/5A-3000/5A; (settable).

Sensitivity: 100mA

Measurement precision:

Voltage: ±1.0%

Current: ±1.0%

Power factor: ±1.0%

Reactive power: ±2.0%